Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/8638
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGokgoz, Mehmet Buraken_US
dc.contributor.authorAlemdaroglu, Bahadiren_US
dc.contributor.authorOzmeric, Ahmeten_US
dc.contributor.authorIltar, Serkanen_US
dc.contributor.authorErbay, Fatma Kübraen_US
dc.contributor.authorDemir, Teyfiken_US
dc.date.accessioned2022-07-30T16:43:40Z-
dc.date.available2022-07-30T16:43:40Z-
dc.date.issued2022-
dc.identifier.citationGökgöz, M. B., Alemdaroğlu, B., Özmeriç, A., İltar, S., Erbay, F. K., & Demir, T. (2022). The Effect of Lateralization of a Pelvic Brim Plate on the Fixation of an Anterior Column Fracture: A Biomechanical Analysis. Cureus, 14(4).en_US
dc.identifier.issn2168-8184-
dc.identifier.urihttps://doi.org/10.7759/cureus.24158-
dc.identifier.urihttps://hdl.handle.net/20.500.11851/8638-
dc.description.abstractObjectives Anterior column fractures can be seen as either isolated or accompanied by many types of complex acetabulum fractures. The aim of this study was to biomechanically compare the stability of a standard pelvic brim plate with a more laterally located suprapectineal plate, which is more commonly used in minimally invasive application, on an intermediate height anterior column fracture model under dynamic and static loading. Materials and methods Right side, adult, foam cortical shell artificial hemipelvis models were used (Sawbones, Pacific Research Laboratories, Vashon, WA, USA). Twenty-four (24) pieces of foam cortical shell artificial hemipelvis models were separated into three groups (M, L, and control). In group M, a suprapectineal plate was placed medially just adjacent to the pelvic brim. In group L, a laterally located suprapectineal plate was placed 2 cm lateral of the pelvic brim at its most proximal point. Then, dynamic load testing of 1000 cycles between 50 N and 500 N force and a static load test of 1.2 kN at 2 mm/minute were applied. Dynamic and static tests were conducted on an axial compression device. Displacements were measured after dynamic and static loading conditions. Results In the dynamic loading test at the AL point (superior intersection of the fracture line with the acetabular roof), the median displacement was significantly higher in group L than in group M (0.12 (IQR: 0.058-0.8125) mm and 0.04 (IQR: 0.03-0.065) mm (p = 0.02)). There was no other statistically significant difference in the displacement amounts in both dynamic and static loading conditions at other measurement points. The comparison of the stiffness of the M and L groups showed no statistically significant results, while the control group was significantly more rigid than both the M and L groups (p = 0.04 for both). None of the artificial hemipelvis models was found to be fractured at the end of the test. Conclusion Suprapectineal plates, placed on either the medial or lateral aspect of the pelvic brim, may be used for the fixation of anterior column-type fractures to provide rigid fixation and stability. As plate location did not impact stiffness and stability, the results suggest that surgeons have flexibility in determining the fixation based on accessibility, fracture pattern, and surgeon experience.en_US
dc.description.sponsorshipTurkish Society of Orthopaedics and Traumatology (TSOT); Turkish Orthopaedics Research Council (TORC)en_US
dc.description.sponsorshipWe would like to thank the Turkish Society of Orthopaedics and Traumatology (TSOT) and the Turkish Orthopaedics Research Council (TORC) for the funding of this research.en_US
dc.language.isoenen_US
dc.publisherCureus Incen_US
dc.relation.ispartofCureus Journal of Medical Scienceen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectopen reduction internal fixationen_US
dc.subjectbiomechanicalen_US
dc.subjectsuprapectineal plateen_US
dc.subjectanterior columnen_US
dc.subjectacetabular fracturesen_US
dc.subjectAcetabular Fracturesen_US
dc.subjectInternal-Fixationen_US
dc.subjectReductionen_US
dc.subjectSystemsen_US
dc.subjectScrewen_US
dc.titleThe Effect of Lateralization of a Pelvic Brim Plate on the Fixation of an Anterior Column Fracture: a Biomechanical Analysisen_US
dc.typeArticleen_US
dc.departmentFaculties, Faculty of Engineering, Department of Mechanical Engineeringen_US
dc.identifier.volume14en_US
dc.identifier.issue4en_US
dc.identifier.wosWOS:000789853600008en_US
dc.institutionauthorErbay Elibol, Fatma Kübraen_US
dc.institutionauthorDemir, Teyfiken_US
dc.identifier.pmid35592198-
dc.identifier.doi10.7759/cureus.24158-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
item.openairetypeArticle-
item.languageiso639-1en-
item.grantfulltextnone-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
Appears in Collections:Biyomedikal Mühendisliği Bölümü / Department of Biomedical Engineering
Makine Mühendisliği Bölümü / Department of Mechanical Engineering
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

WEB OF SCIENCETM
Citations

3
checked on Dec 21, 2024

Page view(s)

142
checked on Dec 16, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.