dc.contributor.authorEr, Mehmet Serhan-
dc.contributor.authorAltınel, Levent-
dc.contributor.authorEroğlu, Mehmet-
dc.contributor.authorVerim, Özgür-
dc.contributor.authorDemir, Teyfik-
dc.contributor.authorAtmaca, Halil-
dc.date.accessioned2021-09-11T15:57:54Z-
dc.date.available2021-09-11T15:57:54Z-
dc.date.issued2014-
dc.identifier.issn1749-799X-
dc.identifier.urihttps://doi.org/10.1186/1749-799X-9-48-
dc.identifier.urihttps://hdl.handle.net/20.500.11851/7567-
dc.description.abstractBackground: The purpose of the present study was to compare the results of various types of anchor applications with or without augmentation in both osteopenic and severely osteoporotic bone models. Methods: Two different types of suture anchors were tested in severely osteoporotic (SOP) and osteopenic polyurethane (PU) foam blocks using an established protocol. An Instron machine applied static loading parallel to the axis of insertion until failure, and the mean anchor failure strengths were calculated. The mode of failure (anchor pullout, suture tear) was recorded. The anchors tested included the Corkscrew (R) (CS) (Arthrex Inc., Naples, FL, USA) (without augmentation, polymethylmethacrylate (PMMA)-augmented, and bioabsorbable tricalcium phosphate (TCP) cement-augmented) and Corkscrew (R) FT II (CS FT II) 5.5 mm (without augmentation as used routinely). Results: The mean failure loads for both SOP and osteopenic PU foam blocks, respectively, were as follows: CS, 16.2 and 212.4 N; CS with TCP, 75.2 and 396 N; CS with PMMA, 101.2 and 528.8 N; CS FT II, 13.8 and 339.8 N. Conclusions: Augmentation of CS with TCP or PMMA would be essential to SOP bones. In the osteopenic bone model, although anchor fixation augmented with PMMA is the best fixation method, CS augmented with TCP cement or CS FT II without any need for augmentation may also be used as an alternative.en_US
dc.language.isoenen_US
dc.publisherBmcen_US
dc.relation.ispartofJournal of Orthopaedic Surgery And Researchen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectSuture anchoren_US
dc.subjectPullouten_US
dc.subjectOsteoporosisen_US
dc.subjectRotator cuff repairen_US
dc.subjectTricalcium phosphate cementen_US
dc.subjectBoneen_US
dc.titleSuture Anchor Fixation Strength With or Without Augmentation in Osteopenic and Severely Osteoporotic Bones in Rotator Cuff Repair: a Biomechanical Study on Polyurethane Foam Modelen_US
dc.typeArticleen_US
dc.departmentFaculties, Faculty of Engineering, Department of Mechanical Engineeringen_US
dc.departmentFakülteler, Mühendislik Fakültesi, Makine Mühendisliği Bölümüen_US
dc.identifier.volume9en_US
dc.identifier.wosWOS:000349483300001-
dc.identifier.scopus2-s2.0-84908296773-
dc.institutionauthorDemir, Teyfik-
dc.identifier.pmid25148925-
dc.identifier.doi10.1186/1749-799X-9-48-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopusqualityQ2-
dc.identifier.wosqualityQ2-
item.fulltextNo Fulltext-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeArticle-
item.grantfulltextnone-
crisitem.author.dept02.7. Department of Mechanical Engineering-
Appears in Collections:Makine Mühendisliği Bölümü / Department of Mechanical Engineering
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

26
checked on Mar 29, 2025

WEB OF SCIENCETM
Citations

24
checked on Jan 11, 2025

Page view(s)

74
checked on Mar 31, 2025

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.