Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/5921
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPramuanjaroenkij, Anchasa-
dc.contributor.authorWongpanit, K.-
dc.contributor.authorPhonong, G.-
dc.contributor.authorChaiburi, B.-
dc.contributor.authorKakaç, S.-
dc.date.accessioned2021-09-11T15:20:47Z-
dc.date.available2021-09-11T15:20:47Z-
dc.date.issued2013en_US
dc.identifier.citationASME 2013 4th International Conference on Micro/Nanoscale Heat and Mass Transfer, MNHMT 2013, 11 December 2013 through 14 December 2013, Hong Kong, 105445en_US
dc.identifier.urihttps://doi.org/10.1115/MNHMT2013-22240-
dc.identifier.urihttps://hdl.handle.net/20.500.11851/5921-
dc.description.abstractIn this work, the reusable Lab-on-a-Chip or LOC was fabricated and developed to reduce its investment cost and to ease its operations. A sandwiched acrylic set was chosen to assemble the PDMS LOC which was aimed to investigate biological samples, especially the samples from animals. Chicken and sheep blood were chosen as the samples to implement two-phase flows with different red-blood-cell shapes. The chicken blood flow represented the viscous twophase flow with the oval shape particles while the sheep blood flow represented the inadhesive samples with the round particles. The LOC electrodes from different materials as the sputtered nickel plate, the aluminium foil, the copper plate, and the gold foil were examined. Ratios between the anticoagulant solution and the biological samples were studied to find their effects on sample velocities and to find the best image to characterize the RBC flow behaviors. Since it was hard to characterize the particle flow in the inadhesive flows, the result pictures were analyzed and presented in terms of color intensities per unit area by using a computer program called "ImageJ". The sheep-blood-flow results were validated with the hematology results which were the hematocrits to find their relationships between the hematocrits and the RBC flows. Among different LOC electrodes, the sputtered nickel electrodes were the most suitable electrodes in this current application. We found that the suitable anticoagulant-sample ratios for chicken and sheep samples were 5:1 and 1:1 by volume, respectively. The normal-health-condition sheep with the standard hematocrits higher than 28% showed the averagedifferent- color intensities per unit area between cathode and anode at 39.485 pixels per unit area while the lower standard hematocrit samples, the hematocrits were lower than 28%, showed the average-different-color intensities at 14.641 pixels per unit area, the lower intensity the lower hematocrit. So the LOC coupled with "ImageJ" exhibited their capabilities to investigate the sheep blood conditions, especially, this coupled technique consumed less time than the traditional hematology process. Copyright © 2013 by ASME.en_US
dc.description.sponsorshipHeat Transfer Divisionen_US
dc.language.isoenen_US
dc.publisherAmerican Society of Mechanical Engineers (ASME)en_US
dc.relation.ispartofASME 2013 4th International Conference on Micro/Nanoscale Heat and Mass Transfer, MNHMT 2013en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleRelationships Between Hematocrit and Sample Flows on Lab-Onen_US
dc.typeConference Objecten_US
dc.departmentFaculties, Faculty of Engineering, Department of Mechanical Engineeringen_US
dc.departmentFakülteler, Mühendislik Fakültesi, Makine Mühendisliği Bölümütr_TR
dc.identifier.scopus2-s2.0-84901774589en_US
dc.institutionauthorKakaç, Sadık-
dc.identifier.doi10.1115/MNHMT2013-22240-
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.relation.conferenceASME 2013 4th International Conference on Micro/Nanoscale Heat and Mass Transfer, MNHMT 2013en_US
item.openairetypeConference Object-
item.languageiso639-1en-
item.grantfulltextnone-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
crisitem.author.dept02.7. Department of Mechanical Engineering-
Appears in Collections:Makine Mühendisliği Bölümü / Department of Mechanical Engineering
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Show simple item record



CORE Recommender

Page view(s)

56
checked on Dec 16, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.