Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.11851/5602
Title: | Biomechanical performance of various cement-augmented cannulated pedicle screw designs for osteoporotic bones | Authors: | Tolunay, T. Arslan, K. Yaman, O. Dalbayrak, Sedat Demir, Teyfik |
Keywords: | Cement augmentation Pedicle screw design Pullout |
Publisher: | Elsevier Inc. | Abstract: | Introduction Early-stage pullout is a common problem for surgeons during the fixation of osteoporotic bones. Poor bone quality limits the use of pedicle screws for patients with osteoporosis. In this study, the researchers investigated the effects of hole and gap position and type on the pullout strength of cannulated screws. Methods Seven different designs were tested, including a control group. All cannula diameters were 2 mm and holes were drilled with a diameter of 1.5 mm. Gaps were milled with a 2-mm-diameter tool with 2-mm displacement proximally. All holes and gaps were drilled or opened unilaterally and bilaterally. Grade 40 and 10 polyurethane foam was used to simulate healthy and osteoporotic bones, respectively. For pullout tests, insertion depth was 30 mm and 2-mm-diameter pilot holes were drilled into blocks before screws were inserted. The cross-head speed was 2 mm/min. For torsion tests, 1 side of the screw was fixed and other was twisted clockwise. Results For torsion tests, the maximum torque value exhibited by the control group (non-cannulated) was 14.94 Nm. The highest torsional strength among tested cannulated screws was 13.54 Nm for Single side two holes including design (S2H) (p <.0001). The minimum torsional strength was 9.45 Nm with a breaking angle of 39° (p <.005). Comparing results for samples pulled out from grade 40 polyurethane foam, single side slot including design (SS) samples exhibited the highest pullout strength with a maximum force of 3,104 N. Conclusions The unilateral, sequential, 3-radial hole, drilled, cannulated screw was the optimal alternative when considering pullout and torsional strength as criteria. © 2015 Scoliosis Research Society. | URI: | https://doi.org/10.1016/j.jspd.2014.09.055 https://hdl.handle.net/20.500.11851/5602 |
ISSN: | 2212-134X |
Appears in Collections: | Makine Mühendisliği Bölümü / Department of Mechanical Engineering Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection |
Show full item record
CORE Recommender
SCOPUSTM
Citations
10
checked on Nov 9, 2024
Page view(s)
150
checked on Nov 11, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.