Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/3995
Title: The Comparison of Bacterial Contamination and Antibacterial Effi Cacy of the Anti-Glaucomatous Eyedrops With and Without Preservatives
Authors: Özülken, Kemal
Çubuk, Mehmet Özgür
İnan, Neşe
Acar, Uğur
Göçmen, Jülide Sedef
Akman, Ahmet
Keywords: Benzalkonium chloride
Brimonidine
Glaucoma
Purite
Multi-dose non-preservative ophthalmic solutions
Publisher: Gazi Eye Foundation
Gazi Göz Vakfı
Source: OZULKEN, K., CUBUK, M. O., INAN, N., ACAR, U., GOCMEN, J. S., & AKMAN, A. (2020). The Comparison of Bacterial Contamination and Antibacterial Efficacy of the Anti-Glaucomatous Eyedrops.
Abstract: Purpose: To investigate the bacterial contamination risks and antimicrobial activities of the preservative-free and preservative-containing anti-glaucomatous ophthalmic solutions. Materials and Methods: Ophthalmic solution bottles of preservative-free brimonidine 0.15% (D1), benzalkonium chloride-containing (BAK) brimonidine 0.15% (D2), purite-containing brimonidine 0.15% (D3) and BAK-containing timolol maleate dorzolamide fi xed combination (D4) were included in this study in terms of microbial contamination risk. Moreover, microbial contamination of the two bottles [preservative-free brimonidine 0.15% (D7) and BAK-containing brimonidine 0.15% (D8)] was investigated after contacting their tips with the lower eyelid edge of a researcher. Every day twice a day for 60 days; the caps of the bottles were opened and they were closed after waiting for 20 sec. One drop was added from these six bottles 11 times during the study period (60 days) to the six separate and renewed blood-agar mediums. Microbial contamination was evaluated every visit by examining the blood agar mediums by the same microbiologist. In terms of antimicrobial effi cacy; D1, D2, D3 and D4 were compared with the antibiotic containing ophthalmic solutions; moxifl oxacin (D5) and tobramycin (D6) by using agar well diffusion method. Results: No bacterial growth was observed in the mediums of D1, D2, D3, D4 and D8 bottles. The bacterial growth of methicillin-susceptible and resistant coagulase-negative staphylococci was observed in the medium of D7 bottle on some days. A large inhibition zone was seen around D5 and D6, whereas a smaller inhibition zone was detected around D2 and D4. No inhibition zone was detected around the D1 and D3 bottles. Conclusions: Multi-dose preservative-free antiglaucomatous ophthalmic solutions have not any risk of bacterial contamination unless the tip of the bottle is contaminated.
URI: https://hdl.handle.net/20.500.11851/3995
http://www.glaucomacataractjournal.com/abstract.php?id=871
ISSN: 1305-9173
Appears in Collections:Cerrahi Tıp Bilimleri Bölümü / Department of Surgical Sciences
Temel Tıp Bilimleri Bölümü / Department of Basic Medical Sciences

Show full item record



CORE Recommender

Page view(s)

266
checked on Dec 16, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.