Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.11851/3968
Title: | Capacitive Micromachined Ultrasonic Transducer: Transmission Performance Evaluation Under Different Driving Parameters and Membrane Stress for Underwater Imaging Applications | Authors: | Yaşar, Abdullah İrfan Yıldız, Fikret Eroğul, Osman |
Keywords: | Ultrasonic transducers | Publisher: | Springer Science and Business Media Deutschland GmbH | Source: | Yaşar, A. İ., Yıldız, F., & Eroğul, O. Capacitive micromachined ultrasonic transducer: transmission performance evaluation under different driving parameters and membrane stress for underwater imaging applications. Microsystem Technologies, 1-11. | Abstract: | Transmission performance of a CMUT element in terms of output pressure and displacements was evaluated. A SIMULINK model of single CMUT element based on mechanical model of MEMS capacitor was used and the analyses were performed under different ac and dc conditions. 2.6 µm thick Si, Poly-Si and Si3Ni4 membranes with a radius 60 µm were used to obtain results for underwater imaging application. Relation between membrane stress and outputs of CMUT was also investigated using SIMULINK model for commonly used CMUT membrane made of Si3Ni4 and polysilicon membrane under different electrical driving parameters. It was observed that different ac signal inputs (sine, square and sawtooth) showed different effects on CMUTs pressure and displacement characteristics. Our results indicated that the maximum output pressure and displacement were obtained in a square waveform. In addition, although stress on membrane increases the displacement and pressure of CMUT membrane made of Poly-Si, quality factor inversely proportional to stress on membrane. Membrane stress has adverse effect on Si3Ni4 membrane transmission outputs. The used model in this study might enable to determine optimum driving electrical inputs and stress on membrane to control CMUT outputs in terms of output pressure, displacement, quality factor and bandwitdh. | URI: | https://hdl.handle.net/20.500.11851/3968 https://doi.org/10.1007/s00542-020-04827-4 |
ISSN: | 0946-7076 |
Appears in Collections: | Biyomedikal Mühendisliği Bölümü / Department of Biomedical Engineering Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Show full item record
CORE Recommender
SCOPUSTM
Citations
1
checked on Dec 21, 2024
WEB OF SCIENCETM
Citations
3
checked on Dec 21, 2024
Page view(s)
178
checked on Dec 16, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.