Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.11851/3684
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Özgüzar, Hatice Ferda | - |
dc.contributor.author | Can, Gizem Kaleli | - |
dc.contributor.author | Kabay, Gözde | - |
dc.contributor.author | Mutlu, Mehmet | - |
dc.date.accessioned | 2020-09-17T14:43:36Z | - |
dc.date.available | 2020-09-17T14:43:36Z | - |
dc.date.issued | 2019-06 | - |
dc.identifier.citation | Özgüzar, H. F., Can, G. K., Kabay, G., & Mutlu, M. (2019). Quartz tuning fork as a mass sensitive biosensor platform with a bi-layer film modification via plasma polymerization. MRS Communications, 9(2), 710-718. | en_US |
dc.identifier.issn | 2159-6859 | - |
dc.identifier.uri | https://hdl.handle.net/20.500.11851/3684 | - |
dc.identifier.uri | https://doi.org/10.1557/mrc.2019.55 | - |
dc.description.abstract | Due to the lack of the stability of amine films, a promising transducer, quartz-tuning fork (QTF) prongs were modified by a bi-layer film of plasma-polymerized n-heptane (hep) and then by ethylenediamine (EDA), respectively. For this purpose, the authors investigate the stability of amine-rich thin films both in air and aqueous medium. EDA films were deposited on QTF substrates by using an RF plasma system. The final amine-rich thin film was used to immobilize biologic recognition element. Model protein studies were showed that selected thin films could be adapted to QTF transducers to be used as a biosensor template. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Cambridge University Press | en_US |
dc.relation.ispartof | MRS Communications | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Surface Modification | en_US |
dc.subject | Microscopy | en_US |
dc.subject | Allylamine | en_US |
dc.subject | Stability | en_US |
dc.subject | Ethylene | en_US |
dc.subject | Contact | en_US |
dc.subject | Improve | en_US |
dc.subject | Oxygen | en_US |
dc.title | Quartz Tuning Fork as a Mass Sensitive Biosensor Platform With a Bi-Layer Film Modification Via Plasma Polymerization | en_US |
dc.type | Article | en_US |
dc.department | Faculties, Faculty of Engineering, Department of Biomedical Engineering | en_US |
dc.department | Fakülteler, Mühendislik Fakültesi, Biyomedikal Mühendisliği Bölümü | en_US |
dc.identifier.volume | 9 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.startpage | 710 | en_US |
dc.identifier.endpage | 718 | en_US |
dc.authorid | 0000-0001-7146-1937 | - |
dc.identifier.wos | WOS:000477661800033 | - |
dc.identifier.scopus | 2-s2.0-85065437252 | - |
dc.institutionauthor | Mutlu, Mehmet | - |
dc.identifier.doi | 10.1557/mrc.2019.55 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.scopusquality | Q3 | - |
dc.identifier.wosquality | Q4 | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.fulltext | No Fulltext | - |
item.openairetype | Article | - |
item.grantfulltext | none | - |
crisitem.author.dept | 02.2. Department of Biomedical Engineering | - |
Appears in Collections: | Biyomedikal Mühendisliği Bölümü / Department of Biomedical Engineering Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.