Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/1806
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRodoplu, Didem-
dc.contributor.authorŞen, Yasin-
dc.contributor.authorMutlu, Mehmet-
dc.date.accessioned2019-07-08T13:29:36Z
dc.date.available2019-07-08T13:29:36Z
dc.date.issued2013-04-
dc.identifier.citationRodoplu, D., Sen, Y., & Mutlu, M. (2013). Modification of quartz crystal microbalance surfaces via electrospun nanofibers intended for biosensor applications. Nanoscience and Nanotechnology Letters, 5(4), 444-451.en_US
dc.identifier.issn1941-4900-
dc.identifier.urihttps://doi.org/10.1166/nnl.2013.1558-
dc.identifier.urihttps://hdl.handle.net/20.500.11851/1806-
dc.description.abstractThe major aim of this study is to increase the performance of mass sensitive biosensor surfaces by making modifications on quartz crystal microbalance (QCM) surfaces via electrospinning and plasma polymerization techniques. Polyvinyl alcohol (PVA) nanofibers with a diameter of approximately 150 nm were collected on the QCM surfaces by electrospinning technique. Allylamine monomer was used to create specific groups on these nanofiber coated surfaces by plasma polymerization technique. Modified surfaces were characterized by contact angle measurements, scanning electron microscopy, atomic force microscopy, fourier transform infrared spectroscopy and QCM frequency measurements in order to determine the physical and chemical characteristics of the surfaces after each experimental stage. N-H, C-N, C-H and C=O group bands were determined in the IR spectra of the materials. Decrease in the contact angle values of the modified materials indicated the increase in hydrophilicity. Those results showed that amine containing films on the surfaces were successfully deposited using plasma. The performance of modified QCM surfaces was tested via resonance frequency shifts measurements after bovine serum albumin immobilization. In this group of tests, "dip and dry" method and "flow-cell method" were performed and 548 +/- 4 Hz and 50 +/- 5 Hz frequency shifts were obtained respectively. Results of this study revealed that plasma treated electrospun PVA nanofiber modified surfaces can be used for further biosensor applications.en_US
dc.language.isoenen_US
dc.publisherAmerican Scientific Publishersen_US
dc.relation.ispartofNanoscience and Nanotechnology Lettersen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectElectrospun Nanofibersen_US
dc.subject Plasma Surface Modificationen_US
dc.subject Quartz Crystal Microbalanceen_US
dc.subject Biosensorsen_US
dc.titleModification of Quartz Crystal Microbalance Surfaces Via Electrospun Nanofibers Intended for Biosensor Applicationsen_US
dc.typeArticleen_US
dc.typeConference Objecten_US
dc.departmentFaculties, Faculty of Engineering, Department of Biomedical Engineeringen_US
dc.departmentFakülteler, Mühendislik Fakültesi, Biyomedikal Mühendisliği Bölümüen_US
dc.identifier.volume5en_US
dc.identifier.issue4en_US
dc.identifier.startpage444en_US
dc.identifier.endpage451en_US
dc.authorid0000-0001-7146-1937-
dc.identifier.wosWOS:000317537500004-
dc.identifier.scopus2-s2.0-84877783851-
dc.institutionauthorMutlu, Mehmet-
dc.identifier.doi10.1166/nnl.2013.1558-
dc.authorscopusid57202957646-
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.identifier.scopusqualityN/A-
item.fulltextNo Fulltext-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.cerifentitytypePublications-
item.openairetypeArticle-
item.openairetypeConference Object-
item.grantfulltextnone-
crisitem.author.dept02.2. Department of Biomedical Engineering-
Appears in Collections:Biyomedikal Mühendisliği Bölümü / Department of Biomedical Engineering
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

7
checked on Mar 29, 2025

WEB OF SCIENCETM
Citations

7
checked on Jan 18, 2025

Page view(s)

116
checked on Mar 31, 2025

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.