Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.11851/1533
Title: | Evaluation of the Effect of Fixation Angle Between Polyaxial Pedicle Screw Head and Rod on the Failure of Screw-Rod Connection | Authors: | Çetin, Engin Özkaya, Mustafa Güler, Umit Özgür Acaroğlu, Emre Demir, Teyfik |
Keywords: | Adolescent idiopathic scoliosis Posterior spinal-fusion Finite-element analyses Pullout strength Biomechanical analysis Hook instrumentation Mechanical stability Lumbar spine Complications Deformity |
Publisher: | Hindawi Ltd | Source: | Çetin, E., Özkaya, M., Güler, Ü. Ö., Acaroğlu, E., & Demir, T. (2015). Evaluation of the effect of fixation angle between polyaxial pedicle screw head and rod on the failure of screw-rod connection. Applied bionics and biomechanics, 2015. | Abstract: | Introduction. Polyaxial screws had been only tested according to the ASTM standards (when they were perpendicularly positioned to the rod). In this study, effects of the pedicle screws angled fixation to the rod on the mechanical properties of fixation were investigated. Materials and Method. 30 vertically fixed screws and 30 screws fixed with angle were used in the study. Screws were used in three different diameters which were 6.5 mm, 7.0 mm, and 7.5 mm, in equal numbers. Axial pull-out and flexion moment tests were performed. Test results compared with each other using appropriate statistical methods. Results. In pull-out test, vertically fixed screws, in 6.5 mm and 7.0 mm diameter, had significantly higher maximum load values than angled fixed screws with the same diameters (P < 0.01). Additionally, vertically fixed screws, in all diameters, had significantly greater stiffness according to corresponding size fixed with angle (P < 0.005). Conclusion. Fixing the pedicle screw to the rod with angle significantly decreased the pull-out stiffness in all diameters. Similarly, pedicle screw instrumentation fixed with angle decreased the minimum sagittal angle between the rod and the screw in all diameters for flexion moment test but the differences were not significant. | URI: | https://www.hindawi.com/journals/abb/2015/150649/ https://hdl.handle.net/20.500.11851/1533 |
ISSN: | 1176-2322 |
Appears in Collections: | Makine Mühendisliği Bölümü / Department of Mechanical Engineering PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Show full item record
CORE Recommender
SCOPUSTM
Citations
8
checked on Dec 21, 2024
WEB OF SCIENCETM
Citations
12
checked on Aug 31, 2024
Page view(s)
80
checked on Dec 16, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.