Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/1521
Full metadata record
DC FieldValueLanguage
dc.contributor.authorÇavuşoğlu, Ali Turgay-
dc.contributor.authorErbay, Fatma Kübra-
dc.contributor.authorÖzsoy, Mehmet Hakan-
dc.contributor.authorDemir, Teyfik-
dc.date.accessioned2019-06-26T08:07:04Z
dc.date.available2019-06-26T08:07:04Z
dc.date.issued2017-10
dc.identifier.citationÇavuşoğlu, A. T., Erbay, F. K., Özsoy, M. H., & Demir, T. (2017). Biomechanical comparison of supraacetabular external fixation and anterior pelvic bridge plating. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 231(10), 931-937.en_US
dc.identifier.issn0954-4119
dc.identifier.urihttps://doi.org/10.1177/0954411917718223-
dc.identifier.urihttps://hdl.handle.net/20.500.11851/1521-
dc.description.abstractUnstable pelvic ring injuries are complex and risky injuries due to high morbidity and mortality. Although anterior pelvic external fixator is a suitable method for rapid stabilization of an injured pelvic ring, due to some disadvantages such as high complication rate, nerve damage, and difficulties of patient's mobility and comfort, there has recently been increased searching for alternative methods for stabilization of the pelvic ring. Pubic symphysis zone freely moves in pelvic models. This study aims to evaluate the biomechanical stability of anterior pelvic bridge plating and compare it with supraacetabular external fixators in an untreated unstable pelvic fracture model. Samples were loaded statically with 2-mm/min loading rate in single leg standing position. Maximum load was 2.3 kN. When loading the samples, photographs were taken continuously. Stiffness values were calculated from the load displacement curves. Some reference parameters were described and were measured from unloaded and 2.3-kN-loaded photographs of the test. The mean stiffness values were 491.14 +/- 52.22, 478.55 +/- 41.44, and 470.25 +/- 44.51 N/mm for anterior pelvic bridge plating group, supraacetabular external fixator group, and Control group, respectively. According to the measured parameters from photographs, the mean displacement at the pubic symphysis was 4.7 +/- 0.32, 15.8 +/- 2.01, and 18.2 +/- 0.47mm for anterior pelvic bridge plating, supraacetabular external fixator, and Control group, respectively. The highest displacement in the pubic symphysis was found in Control group, and minimum displacement was observed in anterior pelvic bridge plating group. When the perpendicular distance between the right and left lower end of ischium was examined, it was observed that displacement was minimum in anterior pelvic bridge plating group compared to other two groups, regarding to the high stability of pubic symphysis. In conclusion, this study revealed superiority of anterior subcutaneous plate fixation with biomechanical results.en_US
dc.language.isoenen_US
dc.publisherSage Publications Ltden_US
dc.relation.ispartofProceedings Of The Institution Of Mechanical Engineers Part H-Journal Of Engineering In Medicineen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPelvisen_US
dc.subjectunstableen_US
dc.subjectbiomechanicsen_US
dc.subjectsupraacetabular external fixationen_US
dc.subjectanterior pelvic bridge platingen_US
dc.titleBiomechanical Comparison of Supraacetabular External Fixation and Anterior Pelvic Bridge Platingen_US
dc.typeArticleen_US
dc.departmentFaculties, Faculty of Engineering, Department of Mechanical Engineeringen_US
dc.departmentFakülteler, Mühendislik Fakültesi, Makine Mühendisliği Bölümütr_TR
dc.identifier.volume231
dc.identifier.issue10
dc.identifier.startpage931
dc.identifier.endpage937
dc.authorid0000-0001-6352-8302-
dc.identifier.wosWOS:000418181900001en_US
dc.identifier.scopus2-s2.0-85029682925en_US
dc.institutionauthorDemir, Teyfik-
dc.identifier.pmid28689459en_US
dc.identifier.doi10.1177/0954411917718223-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopusqualityQ2-
item.openairetypeArticle-
item.languageiso639-1en-
item.grantfulltextnone-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
Appears in Collections:Makine Mühendisliği Bölümü / Department of Mechanical Engineering
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

3
checked on Dec 21, 2024

WEB OF SCIENCETM
Citations

7
checked on Aug 31, 2024

Page view(s)

138
checked on Dec 16, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.