Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/1320
Title: Development of an Advanced Circuit Model for Superconducting Strip Line Detector Arrays
Authors: Bozbey, Ali
Kita, Yuma
Kamiya, Kyohei
Kozaka, Misaki
Tanaka, Masamitsu
Ishida, Takekazu
Fujimaki, Akira
Keywords: SSLD
kinetic inductance detectors
SFQ
superconductors
neutron detector
Publisher: IEICE-Inst Electronics Information Communications Eng
Source: Bozbey, A., Kita, Y., Kamiya, K., Kozaka, M., Tanaka, M., Ishida, T., & Fujimaki, A. (2016). Development of an Advanced Circuit Model for Superconducting Strip Line Detector Arrays. IEICE Transactions on Electronics, 99(6), 676-682.
Abstract: One of the fundamental problems in many-pixel detectors implemented in cryogenics environments is the number of bias and read-out wires. If one targets a megapixel range detector, number of wires should be significantly reduced. One possibility is that the detectors are serially connected and biased by using only one line and read-out is accomplished by on-chip circuitry. In addition to the number of pixels, the detectors should have fast response times, low dead times, high sensitivities, low inter-pixel crosstalk and ability to respond to simultaneous irradiations to individual pixels for practical purposes. We have developed an equivalent circuit model for a serially connected superconducting strip line detector (SSLD) array together with the read-out electronics. In the model we take into account the capacitive effects due to the ground plane under the detector, effects of the shunt resistors fabricated under the SSLD layer, low pass filters placed between the individual pixels that enable individual operation of each pixel and series resistors that prevents the DC bias current flowing to the read-out electronics as well as adjust the time constants of the inductive SSLD loop. We explain the results of investigation of the following parameters: Crosstalk between the neighbor pixels, response to simultaneous irradiation, dead times, L/R time constants, low pass filters, and integration with the SFQ front-end circuit. Based on the simulation results, we show that SSLDs are promising devices for detecting a wide range of incident radiation such as neurons, X-rays and THz waves in many-pixel configurations.
URI: https://www.jstage.jst.go.jp/article/transele/E99.C/6/E99.C_676/_article
https://hdl.handle.net/20.500.11851/1320
ISSN: 1745-1353
Appears in Collections:Elektrik ve Elektronik Mühendisliği Bölümü / Department of Electrical & Electronics Engineering
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File Description SizeFormat 
Development_AB.pdf1.27 MBAdobe PDFThumbnail
View/Open
Show full item record



CORE Recommender

SCOPUSTM   
Citations

2
checked on Dec 21, 2024

WEB OF SCIENCETM
Citations

3
checked on Dec 21, 2024

Page view(s)

138
checked on Dec 16, 2024

Download(s)

98
checked on Dec 16, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.