Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11851/12565
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBozbaş, H.-
dc.contributor.authorAsfour, M.-
dc.contributor.authorÇelebi, S.A.-
dc.date.accessioned2025-07-10T19:48:07Z-
dc.date.available2025-07-10T19:48:07Z-
dc.date.issued2025-
dc.identifier.issn1016-5169-
dc.identifier.urihttps://doi.org/10.5543/tkda.2024.06464-
dc.identifier.urihttps://hdl.handle.net/20.500.11851/12565-
dc.description.abstractThe main disadvantage of bioprosthetic heart valves is their potential for degeneration in the medium to long term. Due to the high risk associated with reoperation, the percutaneous valve-in-valve (ViV) approach is preferred for patients with bioprosthetic degeneration following tricuspid valve replacement. However, the procedure can be challenging when the implanted bioprosthetic valve is not radio-opaque. We present three cases performed at our hospital, detailing a step-by-step approach and alignment techniques when the valve is not visible on fluoroscopy. All patients were admitted with right heart failure and demonstrated severe dysfunction of their tricuspid bioprosthetic valves. In the first case, the bioprosthetic valve was clearly visible on fluoroscopy, which facilitated the alignment process. In the other two cases, the valves were not visible. Predilation was performed, and the resulting indentation line served as a reference. Echocardiographic (ECHO) imaging, along with right atrial and ventricular angiograms, was used to guide the alignment of the balloon-expandable valve. The ViV procedure was successful in all three cases. The transcatheter ViV approach appears to be an effective treatment option for patients with tricuspid bioprosthetic valve degeneration. In cases where the valve is not radio-opaque, the procedure can be safely performed by using the indentation point from balloon dilatation, right ventricular and atrial angiography, and transthoracic or transesophageal echocardiography to guide valve alignment. © 2025 Turkish Society of Cardiology. All rights reserved.en_US
dc.language.isoenen_US
dc.publisherTurkish Society of Cardiologyen_US
dc.relation.ispartofTurk Kardiyoloji Dernegi Arsivien_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBioprosthetic Valve Dysfunctionen_US
dc.subjectPercutaneous Valve Replacementen_US
dc.subjectTricuspid Bioprosthetic Valveen_US
dc.subjectTricuspid Valve-In-Valveen_US
dc.titleTricuspid Valve-In Procedure: What To Do When the Bioprosthetic Valve Is Not Visible on Fluoroscopy? Challenges and Step-By Description of the Procedureen_US
dc.typeArticleen_US
dc.departmentTOBB University of Economics and Technologyen_US
dc.identifier.volume53en_US
dc.identifier.issue4en_US
dc.identifier.startpage286en_US
dc.identifier.endpage290en_US
dc.identifier.scopus2-s2.0-105008255052-
dc.identifier.pmid40459128-
dc.identifier.doi10.5543/tkda.2024.06464-
dc.authorscopusid6603111179-
dc.authorscopusid59518446900-
dc.authorscopusid24400864700-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopusqualityQ3-
dc.identifier.wosqualityN/A-
item.cerifentitytypePublications-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.languageiso639-1en-
item.openairetypeArticle-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
crisitem.author.dept03.07. Department of Cardiology-
Appears in Collections:PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Show simple item record



CORE Recommender

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.